DFRobot Gravity: analog electrical conductivity sensor/meter(K=10) is particularly used to measure the high electrical conductivity liquid, such as seawater, concentrated brine, etc. The measurement range is up to 100ms/cm. This product is suitable for the water quality application of mariculture, for example, marine fisheries, marine aquariums. You may also check Liquid Sensor Selection Guide to get better familar with our liquid sensor series.
It supports 3~5v wide voltage input, and is compatible with 5V and 3.3V main control board, such as Arduino and Raspberry Pi. The excitation source adopts AC signal, which effectively reduces the polarization effect, improves the precision and prolongs the life of the probe; The software library uses single-point calibration method, and can automatically identify standard buffer solution, so simple and convenient.
With this product, main control board (such as Arduino) and the software library, you can quickly build an electrical conductivity meter, plug and play, no solding required, which providing a set of plug-and-play conductivity measurement solution for makers.
DFRobot provides a variety of water quality sensor products, uniform size and interface, not only meet the needs of various water quality testing, but also suitable for the DIY of multi-parameter water quality tester.
Tips:
This product does not contain a temperature sensor. In order to ensure the measurement accuracy, it is strongly recommended to add a temperature sensor to measure the temperature, and achieve automatic temperature compensation. DS18B20 waterproof temperature sensor can be used.
Arduino Connection Diagram
Attention:
1.The probe is a laboratory-grade probe. Do not immerse in liquid for a long time. Otherwise this will shorten the life of the probe.
2.Platinum black layer is attached to the surface of the sheet metal in the probe. It should avoid any object touching it. It can only be washed with distilled water, otherwise the platinum black layer will be damaged, resulting in inaccurate measurement.
Features
3.0~5.0V wide voltage input,0~3.2V output voltage, which is compatible with 5V and 3.3V main board
AC excitation source, effectively reduce polarization
Gravity connector and BNC connector, plug and play, no welding
Software library supports single-point calibration, and automatically identifies standard buffer solution, integrates temperature compensation algorithm
Uniform size and connector , convenient for the design of mechanical structures
Specification
Signal Conversion Board
Supply Voltage: 3.0~5.0V
Output Voltage: 0~3.2V
Probe Connector: BNC
Signal Connector: PH2.0-3Pin
Measurement Accuracy: ¡À5% F.S.
Board size: 42mm*32mm/1.65in*1.26in
Electrical Conductivity Probe
Probe Type: Laboratory Grade
Cell Constant: 10¡À2
Support Detection Range: 10~100ms/cm
Temperature Range: 0~40¡ãC
Probe Life: >0.5 year (Actual life is related to frequency of use and scene)
Cable Length: 100¡À2cm
Shipping List
Electrical Conductivity Probe(K=10, Laboratory Grade) x1
Signal Conversion Board x1
Standard Buffer Solution 12.88ms/cm x4
Gravity Analog Sensor Cable x1
Waterproof Gasket x2
Screw Cap for BNC Connector x1
M3 * 10 nylon pillar x4
M3 * 5 screw x8
DFRobot Gravity: analog electrical conductivity sensor/meter(K=10) is particularly used to measure the high electrical conductivity liquid, such as seawater, concentrated brine, etc. The measurement range is up to 100ms/cm. This product is suitable for the water quality application of mariculture, for example, marine fisheries, marine aquariums. You may also check Liquid Sensor Selection Guide to get better familar with our liquid sensor series.
It supports 3~5v wide voltage input, and is compatible with 5V and 3.3V main control board, such as Arduino and Raspberry Pi. The excitation source adopts AC signal, which effectively reduces the polarization effect, improves the precision and prolongs the life of the probe; The software library uses single-point calibration method, and can automatically identify standard buffer solution, so simple and convenient.
With this product, main control board (such as Arduino) and the software library, you can quickly build an electrical conductivity meter, plug and play, no solding required, which providing a set of plug-and-play conductivity measurement solution for makers.
DFRobot provides a variety of water quality sensor products, uniform size and interface, not only meet the needs of various water quality testing, but also suitable for the DIY of multi-parameter water quality tester.
Tips:
This product does not contain a temperature sensor. In order to ensure the measurement accuracy, it is strongly recommended to add a temperature sensor to measure the temperature, and achieve automatic temperature compensation. DS18B20 waterproof temperature sensor can be used.
Arduino Connection Diagram
Attention:
1.The probe is a laboratory-grade probe. Do not immerse in liquid for a long time. Otherwise this will shorten the life of the probe.
2.Platinum black layer is attached to the surface of the sheet metal in the probe. It should avoid any object touching it. It can only be washed with distilled water, otherwise the platinum black layer will be damaged, resulting in inaccurate measurement.
Features
3.0~5.0V wide voltage input,0~3.2V output voltage, which is compatible with 5V and 3.3V main board
AC excitation source, effectively reduce polarization
Gravity connector and BNC connector, plug and play, no welding
Software library supports single-point calibration, and automatically identifies standard buffer solution, integrates temperature compensation algorithm
Uniform size and connector , convenient for the design of mechanical structures
Specification
Signal Conversion Board
Supply Voltage: 3.0~5.0V
Output Voltage: 0~3.2V
Probe Connector: BNC
Signal Connector: PH2.0-3Pin
Measurement Accuracy: ¡À5% F.S.
Board size: 42mm*32mm/1.65in*1.26in
Electrical Conductivity Probe
Probe Type: Laboratory Grade
Cell Constant: 10¡À2
Support Detection Range: 10~100ms/cm
Temperature Range: 0~40¡ãC
Probe Life: >0.5 year (Actual life is related to frequency of use and scene)
Cable Length: 100¡À2cm
Shipping List
Electrical Conductivity Probe(K=10, Laboratory Grade) x1
Signal Conversion Board x1
Standard Buffer Solution 12.88ms/cm x4
Gravity Analog Sensor Cable x1
Waterproof Gasket x2
Screw Cap for BNC Connector x1
M3 * 10 nylon pillar x4
M3 * 5 screw x8
RETURNS POLICY
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.
SHIPPING
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.